GORE-TEX — Testing and specifications

A comparison starts when the specimen, the edition and the unit are visible.

How to read a weather-laminate sheet

Four behaviours that do not substitute for one another
Dimension What the number describes What to place beside it
Liquid resistance Hydrostatic pressure, often ISO 811:2018 or AATCC 127 Unit, face side, and whether a seam was included
Vapour movement Ret from ISO 11092, or a named JIS L 1099 method Conditioning, gradient and the unit on the sheet
Surface wear Martindale cycles to an end point under ISO 12947 End-point type and whether the membrane was checked after
Dimensions Change in length and width after a stated treatment Specimen size, wash or heat cycle, and usable width
Air flow Air permeability under ASTM D737 when that property is specified Pressure drop and the face that was clamped

Put the edition beside the result

ISO 811:2018 measures resistance to water penetration by hydrostatic pressure. The figure is useful when the pressure unit and the side that faced the water are written down. AATCC 127 is a related hydrostatic procedure with its own reporting habits. AATCC 35 sprays water under a rain condition and scores penetration differently. Copying a single millimetre or kilopascal value from one of these into a cell labeled for another method creates a false comparison. Record the edition year that is printed on the report. If the sheet says only hydrostatic, ask which document was followed.

Keep a target out of the evidence column

A development brief may ask for a shell below a stated Ret, or for a face at 80 g/m2 plus or minus a tolerance the buyer chooses. That sentence is a target. A laboratory line is a result for one specimen in one state. Mixing them lets a wish look like a measurement. For gore tex fabrics, write the target on the brief and attach any supplied report as a separate file with its construction name. GSM, usable width in centimetres, and fibre composition as percent by mass are specification fields. They still need the specimen identity before they become acceptance criteria.

Three builds, four questions

Compare a polyurethane-coated face, an ePTFE laminate and an ePE laminate on the same four questions: liquid barrier, vapour path, hand after flex, and seam sealing. The coated route is often discussed through coating add-on and adhesion. The laminated routes are discussed through membrane, bond and the backing. An ePE layer is not an automatic replacement for an ePTFE layer. If a document uses the phrase gore-tex epe membrane, treat it as a request to identify that functional layer and the textiles bonded to it. A lighter 2.5-layer build, sometimes sought as gore-tex paclite fabric, changes packed volume and the inner surface. It does not inherit the abrasion end point of a heavier 3-layer alpine shell.

Tear strength (ISO 13937) and tensile strength answer seam and panel loads. They do not answer colourfastness or pilling. Air permeability matters only when the brief asks for airflow rather than a continuous barrier. A membrane that blocks liquid water can also restrict air. Say which of those outcomes the end use actually needs.

Scope before a label is reused

A report covers the holder, the products named, and the date. It does not travel to a different face weight because the membrane word looks familiar. This website does not hold out a certificate number, a patent, or a mill identity. When a buyer needs those, the enquiry should ask for the document rather than assume it. Price sits outside the test table. A gore-tex fabric price discussion can follow once layer count, width and quantity are known. It is not a fifth test method, and no public list price is stated here.

Discuss this material question